Specifications
Ring
Base Materials
All
using steel hollow, angle and plate fabricated to the desired dimension as
per our detail shop-drawings and all steel work shall comply with the
requirements of BS 449 Part 1.
Structural weldable
steel hot-rolled material shall be conforming to BS 4360
Part 1: 1969 Grade 43C or equivalent or unless otherwise noted.
All
structural steel hot-rolled hollow sections shall be conforming to BS
1387: 1967 or BS 4360 Part 2 or unless other wise noted.
All
steel brackets shall conform to BS 4360 Part 1: 1969 Grade 43C or
equivalent.
All
bolts and nuts shall conform to BS 4190 or BS 3692: 1967.
Welding shall conform to the pertinent sections of BS 3643. All
electrodes shall comply with BS 639. All welds for connection of hollow
members shall full penetration Butt welds unless otherwise noted-
Steel
members, accessories that related under works of this section shall be
treated with primer coating of Micaceous Iron Oxide (MIO) paint and spray
finish with fire rated paint product of ICI or equivalent.
Dome
Structure And Cladding
Wired
Spaceframe Aluminium extrusion structures shall be in accordance with BS
1474 of Alloy AA6063 Tempered T6 and B3 5005; J575, free from perceptible
distortions wave, twist, buckling or other deficiencies of appearance of
performance.
Aluminium sheet 1.2mm thick in accordance with BS 1470 of Alloy 5754 or
ASTM 209M.
All
bolts, nuts, screws and fastenings shall be in accordance with Type
304,Grade A2 of BS 6205 Stainless Steel Cadmium plated or Type 316 Grade
A4 of BS 6106 Stainless Steel.
All
sealant materials shall be one part low module silicone sealant conforming
to Draft BSS 78/1438 and SMC 10 BS 5889.
Compound used for sealing shall be composed of the best quality material
available. Their adhering qualities shall be such that they adhere to
adjacent surfaces throughout the range of temperature changes from 0
degree F - 180 degree F and humidity changes of 5% to 100%.
Sealant shall be Dow Corning one part silicone or approved equal sealant
that will cure to a durable water tight flexible silicone rubber joint
seal that can accommodate + 50% movement for all site applied sealant.
Structural silicone sealant for factory application shall be Dow Coming
two part silicone or approved equivalent.
Aluminium cladding shall be with fluorocarbon coating for Architect's
selection or otherwise noted. The color shall be selected from the
standard pre-formulated or custom color upon requested.
The
top coated surface shall comply with the "Specification for Coated Coil
for Exterior. Building Applications" issued by ECCA (European Coil
Coating Association) or AAMA 605.1 of (American Aluminium Manufacturer
Association) to achieve the quality level.
Fluorocarbon coating shall be factory spray and oven baked of approved
3coat thermally cured fluorocarbon polymeric and pigmented organic coating
systems as follows:-
-
One
coat inhibitive primer to minimum dry film thickness of 5 microns.
-
One
color coat to minimum dry film thickness of 25 microns.
-
One
clear coat of "Kynar 500 / Hylar 5000" Polyvinylidene Fluoride (PVDF) to
minimum dry film thickness of 10 microns.
|